Active Test
The active test is used to determine and identify details of a malfunction, based on self-diagnosis test result sand data obtained in the DATA MONITOR. In response to instructions from CONSULT, instead of those from ABS actuator and electric unit (control unit) on the vehicle, a drive signal is sent to the actuator to check its operation.
- Never perform ACTIVE TEST while driving the vehicle.
- Always bleed air from brake system before active test.
- Never perform active test when system is malfunctioning.
- "TEST IS STOPPED" is displayed approx. 10 seconds after operation start.
- When performing active test again after "TEST IS STOPPED" is displayed, select "BACK".
- ABS warning lamp, brake warning lamp and VDC warning lamp may turn ON during active test. This is not a malfunction.
ABS IN Valve and ABS OUT Valve
When "Up", "Keep" or "Down" is selected on display screen, the following items are displayed when system is normal.
|
Test item |
Display Item |
Display |
||
|
Up |
Keep |
Down |
||
|
FR RH SOL |
FR RH IN SOL |
Off |
On* |
On* |
|
FR RH OUT SOL |
Off |
Off |
On* |
|
|
FR LH SOL |
FR LH IN SOL |
Off |
On* |
On* |
|
FR LH OUT SOL |
Off |
Off |
On* |
|
|
RR RH SOL |
RR RH IN SOL |
Off |
On* |
On* |
|
RR RH OUT SOL |
Off |
Off |
On* |
|
|
RR LH SOL |
RR LH IN SOL |
Off |
On* |
On* |
|
RR LH OUT SOL |
Off |
Off |
On* |
|
*: Immediately after being selected, status is "On". Status changes to "Off" after approx. 2 seconds.
ABS IN Valve (ACT) and ABS OUT Valve (ACT)
When "Up", "ACT KEEP" or "ACT UP" is selected on display screen, the following items are displayed when system is normal.
|
Test item |
Display Item |
Display |
||
|
Up |
ACT KEEP |
ACT UP |
||
|
FR RH SOL (ACT) |
FR RH IN SOL |
Off |
Off |
On* |
|
FR RH OUT SOL |
Off |
Off |
Off |
|
|
CV1 |
Off |
On* |
On* |
|
|
SV1 |
Off |
Off |
On* |
|
|
FR LH SOL (ACT) |
FR LH IN SOL |
Off |
Off |
On* |
|
FR LH OUT SOL |
Off |
Off |
Off |
|
|
CV1 |
Off |
On* |
On* |
|
|
SV1 |
Off |
Off |
On* |
|
|
RR RH SOL (ACT) |
RR RH IN SOL |
Off |
Off |
On* |
|
RR RH OUT SOL |
Off |
Off |
Off |
|
|
CV2 |
Off |
On* |
On* |
|
|
SV2 |
Off |
Off |
On* |
|
|
RR LH SOL (ACT) |
RR LH IN SOL |
Off |
Off |
On* |
|
RR LH OUT SOL |
Off |
Off |
Off |
|
|
CV2 |
Off |
On* |
On* |
|
|
SV2 |
Off |
Off |
On* |
|
*: Immediately after being selected, status is "On". Status changes to "Off" after approx. 2 seconds.
Stop Lamp ON Relay
When "On" or "Off" is selected on display screen, the following items are displayed when system is normal.
|
Test item |
Display Item |
Display |
|
|
On |
Off |
||
|
STOP LAMP ON RELAY |
STOP LAMP ON RELAY |
On |
Off |