For MEXICO: Inspection
- Visually inspect EVAP vapor lines for improper attachment and for cracks, damage, loose connections, chafing and deterioration.
- Check EVAP canister as follows:
- Block port (B). Orally blow air through port (A).
Check that air flows freely through port (C).
- Block port (A). Orally blow air through port (B).
Check that air flows freely through port (C).
- Block port (B). Orally blow air through port (A).
- Inspect fuel tank filler cap vacuum relief valve for clogging, sticking, etc.
- Wipe clean valve housing.
- Check valve opening pressure and vacuum.
Pressure:
15.3 - 20.0 kPa (0.153 - 0.200 bar, 0.156 - 0.204 kg/cm 2 , 2.22 - 2.90 psi)
Vacuum:
-6.0 to -3.3 kPa (-0.060 to -0.033 bar, -0.061 to -0.034 kg/cm 2 , -0.87 to -0.48 psi)
- If out of specification, replace fuel filler cap as an assembly. Refer to Exploded View .
- Check water separator as follows:
- Check visually for insect nests in the water separator air inlet.
- Check visually for cracks or flaws in the appearance.
- Check visually for cracks or flaws in the hose.
- Check that
and
are not clogged by blowing air into
with
, and then
plugged.
- In case of NG in items 2 - 4, replace the parts.NOTE: Do not disassemble water separator.