Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E191. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace ground connection.
- CHECK CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
EVAP control system pressure sensor
Ground
Voltage (V)
Connector
Terminal
B108
3
Ground
Approx. 5
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
3
E152
177
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
Check sensor power supply 3 circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
1
E152
200
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
2
E152
173
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- CHECK RUBBER TUBE
- Disconnect rubber tube connected to EVAP canister vent control valve.
- Check the rubber tube for clogging.
Is the inspection result normal?
YES
GO TO 8.
NO
Clean the rubber tube using an air blower, repair or replace rubber tube.
- CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 9.
NO
Replace EVAP canister vent control valve. Refer to Exploded View .
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 10.
NO
Replace EVAP control system pressure sensor. Refer to Exploded View .
- CHECK IF EVAP CANISTER IS SATURATED WITH WATER
- Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
- Check if water will drain from the EVAP canister
.
: EVAP canister vent control valve
Does water drain from EVAP canister?
YES
GO TO 11.
NO
INSPECTION END
- CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 12.
- DETECT MALFUNCTIONING PART
Check the following.
- EVAP canister for damage
- EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
Repair hose or replace EVAP canister.