Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E191. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace ground connection.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
EVAP control system pressure sensor
Ground
Voltage (V)
Connector
Terminal
B108
3
Ground
Approx. 5
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
3
E152
177
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
Check sensor power supply 3 circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
1
E152
200
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B108
2
E152
173
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace EVAP control system pressure sensor. Refer to Exploded View .