LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2019 >> Q60 Pure, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (DTC/Circuit Diagnosis) (6 Of 13) >> DTC/Circuit Diagnosis >> DTC P0454: EVAP Control System Pressure Sensor >> Diagnosis Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnosis Procedure

  1. CHECK GROUND CONNECTION 
    1. Turn ignition switch OFF.
    2. Check ground connection E191. Refer to Ground Inspection in Circuit Inspection .

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Repair or replace ground connection.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER 
    1. Disconnect EVAP control system pressure sensor harness connector.
    2. Check sensor harness connector for water.

      Water should not exist.

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY 
    1. Turn ignition switch ON.
    2. Check the voltage between EVAP control system pressure sensor harness connector and ground.

      EVAP control system pressure sensor

      Ground

      Voltage (V)

      Connector

      Terminal

      B108

      3

      Ground

      Approx. 5

    Is the inspection result normal?

    YES

    GO TO  5.

    NO

    GO TO 4.

  4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B108

      3

      E152

      177

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    Check sensor power supply 3 circuit. Refer to Diagnosis Procedure .

    NO

    Repair or replace error-detected parts.

  5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B108

      1

      E152

      200

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    Repair or replace error-detected parts.

  6. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
    1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.

      EVAP control system pressure sensor

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B108

      2

      E152

      173

      Existed

    2. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 7.

    NO

    Repair or replace error-detected parts.

  7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 

    Check EVAP control system pressure sensor. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace EVAP control system pressure sensor. Refer to Exploded View .