Driver Side
When a system malfunction is detected, deactivates a part of the system or all functions depending on the malfunctioning part.
When the malfunction condition recovers to the normal condition, the system returns to the normal operation.
|
Display contents of CONSULT |
Fail-safe |
|
B2451: SEAT BLT MTR DR CIRC |
Fully deactivates the whole operation. |
|
B2452: SEAT BLT MTR AS CIRC |
Deactivates a part of comfort function. |
|
B2455: CONTROL UNIT DR |
Stops the operation in the conditions as per the following.*
|
|
B2457: CONTROL UNIT AS |
Deactivates a part of comfort function. |
|
B2458: LOCAL COMM |
Deactivates a part of comfort function. |
|
B2461: VHCL SPEED SIGNAL |
Stops the operation in the conditions as per the following.
|
|
B2466: DR/AS CONTROL UNIT |
Deactivates a part of comfort function. |
|
B2470: SYS HEAT PROTC DR |
|
|
B2473: BRAKE FLUID PRESSURE SIGNAL |
Stops the operation in the conditions as per the following.
|
|
U0126: ST ANG SEN SIG |
Stops the operation in the conditions as per the following.
|
|
U0428: STRG ANGL CAL |
Stops the operation in the conditions as per the following.
|
|
U1000: CAN COMM CURCUIT |
Stops the operation in the conditions as per the following.*
|
* : The deactivation mode differs depending on the internal malfunctioning condition of control unit