DTC Detection Logic
|
DTC |
CONSULT screen terms |
MELCO code |
DTC detection condition |
|||
|
(Trouble diagnosis content) |
[Malfunction type] |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
41 |
Diagnosis condition |
8.5 V < Battery terminal voltage < 19.2 V |
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.048 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
42 |
Diagnosis condition |
Battery terminal voltage > 7.5 V |
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.048 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
43 |
Diagnosis condition |
Battery terminal voltage > 7.5 V |
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.048 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
44 |
Diagnosis condition |
Initial check |
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Motor terminal voltage is the following condition
|
|||||
|
Diagnosis delay time |
0.5 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
45 |
Diagnosis condition |
|
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Internal current is the following condition
|
|||||
|
Diagnosis delay time |
2 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
46 |
Diagnosis condition |
|
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.2 seconds |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
47a |
Diagnosis condition |
|
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.1 second |
|||||
|
C1592 |
09 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[COMPONENT MALFUNCTION] |
47b |
Diagnosis condition |
|
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.2 seconds |
|||||
|
C1592 |
49 |
EPS actuator motor malf (The electric power steering actuator motor has a malfunction.) |
[INTERNAL ELECTRONIC ERROR] |
32, 33 |
Diagnosis condition |
8.5 V < Battery terminal voltage < 19.2 V |
|
Signal (terminal) |
-- |
|||||
|
Threshold |
Control unit detected the following condition.
|
|||||
|
Diagnosis delay time |
0.2 seconds |
|||||