Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace ground connection.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
- Disconnect EVAP control system pressure sensor harness connector.
- Check sensor harness connector for water.
Water should not exist.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
+
-
Voltage
(Approx.)
EVAP control system pressure sensor
Connector
Terminal
B36
3
Ground
5 V
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B36
3
E32
177
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B36
1
E32
200
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
B36
2
E32
173
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check EVAP control system pressure sensor. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace EVAP control system pressure sensor. Refer to Removal and Installation .