Component Function Check
- CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
With CONSULT
Check ("CDL LOCK SW ", "CDL UNLOCK SW") in "DATA MONITOR" mode for "POWER DOOR LOCK SYSTEM" with CONSULT. Refer to Diagnosis Description .
Monitor item
Condition
CDL LOCK SW
LOCK
: ON
UNLOCK
: OFF
CDL UNLOCK SW
LOCK
: OFF
UNLOCK
: ON
Is the inspection result normal?
YES
Power window serial link is OK.
NO
Refer to Diagnosis Procedure .