Component Inspection
- CHECK THROTTLE CONTROL MOTOR
- Turn ignition switch OFF.
- Disconnect electric throttle control actuator harness connector.
- Check resistance between electric throttle control actuator terminals as per the following.
Electric throttle control actuator
Condition
Resistance
Bank
Terminal
1
1
2
Temperature [Deg. C (Deg. F)]
25 (77)
1 - 15 kOhm
2
1
2
Is the inspection result normal?
YES
INSPECTION END
NO
Replace malfunctioning electric throttle control actuator. Refer to INTAKE MANIFOLD COLLECTOR : Exploded View .