Component Inspection
- CHECK FRONT POWER WINDOW SWITCH RH
- Disconnect front power window switch RH connector.
- Check continuity between front power window switch RH terminals under the following conditions:
Terminal
Condition
Continuity
(+)
(-)
3
5
NEUTRAL
No
UP
Yes
4
NEUTRAL
No
DOWN
Yes
Is the inspection result normal?
YES
Inspection End.
NO
Replace front power window switch RH. Refer to Removal and Installation .