DTC Diagnosis Procedure
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness connector.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I
- Turn ignition switch ON.
- Check the voltage between EVAP control system pressure sensor harness connector and ground.
EVAP control system pressure sensor
Ground
Voltage (V)
Connector
Terminal
C17
3
Ground
Approx. 5
Is the inspection result normal?
YES
GO TO 6.
NO
GO TO 3.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
C17
3
E20
125
Existed
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open between ECM and EVAP control system pressure sensor
- Loose or poor connection for each connector and harness
Repair open circuit.
- CHECK SENSOR POWER SUPPLY 3 CIRCUIT
Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
C17
1
E20
148
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 7.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between EVAP control system pressure sensor and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
EVAP control system pressure sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
C17
2
E20
121
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 10.
NO
GO TO 9.
- Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between EVAP control system pressure sensor and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 11.
NO
Replace EVAP control system pressure sensor. Refer to EVAP CANISTER : Removal & Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Inspection .
INSPECTION END