Component Function Check
- INSPECTION START
Do you have CONSULT?
YES
GO TO 2.
NO
GO TO 3.
- CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR
With CONSULT
- Turn ignition switch ON and engine stopped.
- On the CONSULT screen, select "ENGINE">>"ACTIVE TEST">>"WASTEGATE ACTUATOR".
- Operate "Up" or "Down", set "W/G ACTUATOR POSITION B1" to 0.002 m, and make a quick short note of value "V1" of "W/G ACTUATOR POSI SEN B1".
- Operate "Up" or "Down", set "W/G ACTUATOR POSITION B1" to 0.015 m, and make a quick short note of value "V2" of "W/G ACTUATOR POSI SEN B1".
Do the values of "V1" and "V2" change (visually, ACTUATOR SHAFT operates) and "V2" minus "V1" becomes equal to or more than 2.6V?
YES
INSPECTION END
NO
Replace Turbocharger Assembly (do not replace electric wastegate control actuator only). Refer to Component Location .
- CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR
Without CONSULT
- Turn ignition switch OFF.
- Disconnect Wastegate control actuator harness connector.
- While checking the POSITION SENSOR OUT voltage with an oscilloscope, apply a voltage of 12 V to the positive or negative terminal.
Does ACTUATOR SHAFT visually operate and POSITION SENSOR OUT voltage change?
YES
INSPECTION END
NO
Replace Turbocharger Assembly (do not replace electric wastegate control actuator only). Refer to Component Location .