Diagnosis Procedure
- CHECK ENCODER SIGNAL
- Ignition switch ON.
- Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
Signal name
(+)
(-)
Signal
(Reference value)
Main power window and door lock/unlock switch
Connector
Terminal
Encoder signal 1
D6
11
Ground
Refer to following signal
Encoder signal 2
12
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO
GO TO 2.
- CHECK ENCODER SIGNAL CIRCUIT
- Ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch
Front power window motor LH
Continuity
Connector
Terminal
Connector
Terminal
D6
11
D10
4
Yes
12
6
- Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D6
11
No
12
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness.
- CHECK ENCODER POWER SUPPLY
- Connect main power window and door lock/unlock switch connector.
- Ignition switch ON.
- Check voltage between front power window motor LH harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Front power window motor LH
Connector
Terminal
D10
5
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK ENCODER POWER SUPPLY CIRCUIT
- Ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch
Front power window motor LH
Continuity
Connector
Terminal
Connector
Terminal
D6
3
D10
5
Yes
- Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D6
3
No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK GROUND CIRCUIT 1
- Ignition switch OFF.
- Check continuity between front power window motor LH harness connector and ground.
Front power window motor LH
Ground
Continuity
Connector
Terminal
D10
3
Yes
Is the inspection result normal?
YES
Replace front power window motor LH. Refer to Removal and Installation .
NO
GO TO 6.
- CHECK GROUND CIRCUIT 2
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch
Front power window motor LH
Continuity
Connector
Terminal
Connector
Terminal
D6
10
D10
3
Yes
- Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D10
10
No
Is the inspection result normal?
YES
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO
Repair or replace harness.