Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Disconnect 15A fuse (No. 49) from IPDM E/R.
- Check that 15A fuse is not blowing.
Is the fuse blown (open)?
YES>>
Replace the fuse. [Check the power supply if fuse is blown (open) again.]
NO>>
GO TO 2.
- CHECK FUSIBLE LINK
- Turn ignition switch OFF.
- Check that the following fusible link is not blowing.
Location Fuse No. Capacity Fuse and fusible link holder-1 #V 50A #W 50A
Is the fusible link blown (open)?
YES>>
Replace the fuse. [Check the power supply if fusible link is blown (open) again.]
NO>>
GO TO 3.
- CHECK GROUND CONNECTION
Check ground connection E191. Refer to Ground Inspection in Inspection . Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair or replace error-detected parts.
- CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE GROUND CIRCUIT
- Disconnect electric intake valve timing control module harness connectors.
- Check the continuity between electric intake valve timing control module harness connector and ground.
+ - Continuity Electric intake valve timing control module Connector Terminal E154 41 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace error-detected parts.
- CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE POWER SUPPLY
- Reconnect electric intake valve timing control module harness connectors.
- Check the voltage between electric intake valve timing control module harness connector terminals as follows.
Electric intake valve timing control module Voltage Connector + - Terminal E154 39 41 Battery voltage 40
Is the inspection result normal?
YES>>
GO TO 6.
NO>>
Perform trouble diagnosis for power supply circuit.
- CHECK IGNITION SWITCH SIGNAL
Check the voltage between electric intake valve timing control module harness connectors as follows.
Electric intake valve timing control module Condition Voltage + - Connector Terminal Connector Terminal E153 28 E154 41 Ignition switch: ON Battery voltage Ignition switch: OFF 0 V Is the inspection result normal?
YES>>
Check intermittent incident. Refer to Inspection .
NO>>
GO TO 7.
- CHECK IGNITION SWITCH SIGNAL
- Turn ignition switch OFF.
- Disconnect electric intake valve timing control module harness connectors.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and electric intake valve timing control module harness connector.
+ - Continuity IPDM E/R Electric intake valve timing control module Connector Terminal Connector Terminal E123 55 E153 28 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
Perform trouble diagnosis for power supply circuit.
NO>>
Repair or replace error-detected parts.