Diagnosis Procedure
- CHECK ENCODER SIGNAL
-
- Ignition switch ON.
- Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
Signal name (+) (-) Signal(Reference value) Main power window and door lock/unlock switch Connector Terminal Encoder signal 1 D6 11 Ground Refer to following signal Encoder signal 2 12
Is the inspection result normal?
YES>>
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO>>
GO TO 2.
-
- CHECK ENCODER SIGNAL CIRCUIT
-
- Ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 11 D10 4 Yes 12 6 - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch - Continuity Connector Terminal D6 11 Ground No 12
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace harness.
-
- CHECK ENCODER POWER SUPPLY
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
GO TO 4.
- CHECK ENCODER POWER SUPPLY CIRCUIT
-
- Ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 3 D10 5 Yes - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch - Continuity Connector Terminal D6 3 Ground No
Is the inspection result normal?
YES>>
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO>>
Repair or replace harness.
-
- CHECK GROUND CIRCUIT 1
Is the inspection result normal?
YES>>
Replace front power window motor LH. Refer to Removal and Installation .
NO>>
GO TO 6.
- CHECK GROUND CIRCUIT 2
-
- Disconnect main power window and door lock/unlock switch connector.
- Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
Main power window and door lock/unlock switch Front power window motor LH Continuity Connector Terminal Connector Terminal D6 10 D10 3 Yes - Check continuity between main power window and door lock/unlock switch harness connector and ground.
Main power window and door lock/unlock switch - Continuity Connector Terminal D10 10 Ground No
Is the inspection result normal?
YES>>
Replace main power window and door lock/unlock switch. Refer to Removal and Installation .
NO>>
Repair or replace harness.
-