Diagnosis Procedure

  1. CHECK ENCODER SIGNAL 
      1. Ignition switch ON.
      2. Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
        Signal name (+) (-) Signal(Reference value)
        Main power window and door lock/unlock switch
        Connector Terminal
        Encoder signal 1 D6 11 Ground Refer to following signal
        Encoder signal 2 12
        GNSDB110382Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    GO TO 2.

  2. CHECK ENCODER SIGNAL CIRCUIT 
      1. Ignition switch OFF.
      2. Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
      3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D6 11 D10 4 Yes
        12 6
      4. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch - Continuity
        Connector Terminal
        D6 11 Ground No
        12

    Is the inspection result normal?

    YES>>

    GO TO 3.

    NO>>

    Repair or replace harness.

  3. CHECK ENCODER POWER SUPPLY 
      1. Connect main power window and door lock/unlock switch connector.
      2. Ignition switch ON.
      3. Check voltage between front power window motor LH harness connector and ground.
        (+) (-) Voltage(Approx.)
        Front power window motor LH
        Connector Terminal
        D10 5 Ground Battery voltage

    Is the inspection result normal?

    YES>>

    GO TO 5.

    NO>>

    GO TO 4.

  4. CHECK ENCODER POWER SUPPLY CIRCUIT 
      1. Ignition switch OFF.
      2. Disconnect main power window and door lock/unlock switch connector.
      3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D6 3 D10 5 Yes
      4. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch - Continuity
        Connector Terminal
        D6 3 Ground No

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    Repair or replace harness.

  5. CHECK GROUND CIRCUIT 1 
      1. Ignition switch OFF.
      2. Check continuity between front power window motor LH harness connector and ground.
        Front power window motor LH - Continuity
        Connector Terminal
        D10 3 Ground Yes

    Is the inspection result normal?

    YES>>

    Replace front power window motor LH. Refer to Removal and Installation .

    NO>>

    GO TO 6.

  6. CHECK GROUND CIRCUIT 2 
      1. Disconnect main power window and door lock/unlock switch connector.
      2. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D6 10 D10 3 Yes
      3. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch - Continuity
        Connector Terminal
        D10 10 Ground No

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    Repair or replace harness.