Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Pull out 15A fuse (No. 61) from IPDM E/R.
- Check that 15A fuse is not blowing.
Is the fuse blown (open)?
>>
Replace the fuse after repairing the applicable circuit.
>>
GO TO 2.
- CHECK FUSIBLE LINK
- Turn ignition switch OFF.
- Check that the following fusible link is not blowing.
Fusible link No. Capacity #X 40A
Is the fusible link blown (open)?
>>
Replace the fusible link after repairing the applicable circuit.
>>
GO TO 3.
- CHECK GROUND CONNECTION
Check ground connection E15. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
>>
GO TO 4.
>>
Repair or replace error-detected parts.
- CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE GROUND CIRCUIT
- Disconnect electric intake valve timing control module harness connectors.
- Check the continuity between electric intake valve timing control module harness connector and ground.
Electric intake valve timing control module - Continuity Connector Terminal F91 42 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
>>
GO TO 5.
>>
Repair or replace error-detected parts.
- CHECK ELECTRIC INTAKE VALVE TIMING CONTROL MODULE POWER SUPPLY
- Reconnect electric intake valve timing control module harness connectors.
- Check the voltage between electric intake valve timing control module harness connector terminals as follows.
Electric intake valve timing control module Voltage Connector + - Terminal F91 48 42 Battery voltage
Is the inspection result normal?
>>
GO TO 6.
>>
Perform trouble diagnosis for power supply circuit.
- CHECK IGNITION SWITCH SIGNAL
Check the voltage between electric intake valve timing control module harness connectors as follows.
Electric intake valve timing control module Condition Voltage + - Connector Terminal Terminal F91 40 42 Ignition switch: ON Battery voltage Ignition switch: OFF 0 V Is the inspection result normal?
>>
Check intermittent incident. Refer to Intermittent Incident .
>>
GO TO 7.
- CHECK IGNITION SWITCH SIGNAL
- Turn ignition switch OFF.
- Disconnect electric intake valve timing control module harness connectors.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and electric intake valve timing control module harness connector.
IPDM E/R Electric intake valve timing control module Continuity Connector Terminal Connector Terminal E121 43 F91 40 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
>>
Perform trouble diagnosis for power supply circuit.
>>
Repair or replace error-detected parts.