Diagnosis Procedure
- CHECK FUSE
- Turn ignition switch OFF.
- Pull out 15A fuse (No. 61) from IPDM E/R.
- Check that 15A fuse is not blowing.
Is the fuse blown (open)?
>>
Replace the fuse after repairing the applicable circuit.
>>
GO TO 2.
- CHECK FUSE
Is the fuse blown (open)?
>>
Replace the fuse after repairing the applicable circuit.
>>
GO TO 3.
- CHECK GROUND CONNECTION
Check ground connection E15. Refer to Ground Inspection in Circuit Inspection .
Is the inspection result normal?
>>
GO TO 4.
>>
Repair or replace error-detected parts.
- CHECK VCR CONTROL MODULE GROUND CIRCUIT
- Disconnect VCR control module harness connectors.
- Check the continuity between VCR control module harness connector and ground.
VCR control module - Continuity Connector Terminal F90 1 Ground Existed - Also check harness for short to power.
Is the inspection result normal?
>>
GO TO 5.
>>
Repair or replace error-detected parts.
- CHECK VCR CONTROL MODULE POWER SUPPLY
- Reconnect VCR control module harness connectors.
- Check the voltage between VCR control module harness connector terminals as follows.
VCR control module Voltage Connector + - Terminal F90 5 1 Battery voltage
Is the inspection result normal?
>>
GO TO 6.
>>
Perform trouble diagnosis for power supply circuit.
- CHECK IGNITION SWITCH SIGNAL
Check the voltage between VCR control module harness connectors as follows.
VCR control module Condition Voltage + - Connector Terminal Terminal F90 31 1 Ignition switch: ON Battery voltage Ignition switch: OFF 0 V Is the inspection result normal?
>>
Check intermittent incident. Refer to Intermittent Incident .
>>
GO TO 7.
- CHECK IGNITION SWITCH SIGNAL
- Turn ignition switch OFF.
- Disconnect VCR control module harness connectors.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and VCR control module harness connector.
IPDM E/R VCR control module Continuity Connector Terminal Connector Terminal E121 43 F90 31 Existed - Also check harness for short to power and short to ground.
Is the inspection result normal?
>>
Perform trouble diagnosis for power supply circuit.
>>
Repair or replace error-detected parts.