Diagnosis Procedure
- CHECK STOP/START PROHIBIT CAUSE
With CONSULT Select "Stop/Start prohibit cause data recorder" in "WORK SUPPORT" mode of "ENGINE" using CONSULT.
Does "Stop/Start prohibit cause data recorder" show fail-safe?
YES>>
GO TO 2.
NO>>
Check the operating status of system stop / start. Refer to System Description . After confirmation, go to 4.
- CHECK "Stop/Start error" OF CONSULT DATA MONITOR ITEM
With CONSULT
- Select "Stop/Start error" in "Monitor Menu" of "DATA MONITOR" mode in CONSULT.
- Check the displayed data monitor items. Refer to CONSULT Function .
Are there any "NG" monitor items?
YES>>
After confirming the "NG" item, go to 3.
NO>>
GO TO 3.
- CHECK DTC
With CONSULT Perform "All DTC Reading" with CONSULT.
Does it detect the DTC associated with "Stop/Start error" of "DATA MONITOR"?
YES>>
Perform trouble diagnosis of detected DTC. After repairing the defective part, go to 4.
NO>>
GO TO 4.
- CHECK STOP/START INDICATOR / LAMP
Check the stop/start indicator / lamp.
WARNING LAMP/INDICATOR LAMP / INDICATOR CONDITION Stop/start indicator / lamp Not blinking Is the stop/start indicator / lamp blinking?
YES>>
Refer to Symptom Table .
NO>>
INSPECTION END