Work Procedure
If any of the following operations are performed, the initialization is necessary for normal operation of power window system.
- When control unit replaced.
- Electric power supply to power window switch or motor is interrupted by blown fuse or disconnection and connection of the negative terminal of battery, etc.
- Removal and installation of regulator assembly.
- Power supply to the power window main switch or power window motor is cut off by the removal of battery terminal or if the battery fuse is blown (open).
- Disconnection and connection of power window main switch harness connector.
- Removal and installation of motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of door glass.
- Removal and installation of door glass run.
The following specified operations can not be performed under the non-initialized condition.
- Auto-up operation
- Anti-pinch function
- STEP 1
- Close the door.
- Turn ignition switch ON.
- Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
- Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.
- Check that AUTO-UP function operates normally.
>>
GO TO 2.
- STEP 2
Check anti-pinch function. Refer to Work Procedure .
>>
END