DTC Diagnosis Procedure
- INSPECTION START
Confirm the detected malfunction (A or B). Refer to DTC Description . Which malfunction is detected?
A>>
GO TO 2
B>>
GO TO 8.
- CHECK HEATED OXYGEN SENSOR 2 CONNECTOR
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace harness or connectors.
- CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F131 1 F91 43 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F131 2 F92 84 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
HO2S2 ECM Ground Continuity Bank Connector Terminal Connector Terminal 1 F131 2 F92 84 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to Component Inspection . Is the inspection result normal?
YES>>
GO TO 7.
NO>>
GO TO 6.
- REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to EXHAUST MANIFOLD AND THREE WAY CATALYST : Exploded View .
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (NI-43897-18 or NI-43897-12)] and approved anti-seize lubricant (commercial service tool).
>>
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to Inspection .
>>
INSPECTION END
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to Work Procedure .
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 or P0175 detected? Is it difficult to start engine?
YES>>
Perform trouble diagnosis for DTC P0172, P0175. Refer to DTC Description .
NO>>
GO TO 9.
- CHECK HEATED OXYGEN SENSOR 2 GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F131 1 F91 43 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>
GO TO 10.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F131 2 F92 84 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
HO2S2 ECM Ground Continuity Bank Connector Terminal Connector Terminal 1 F131 2 F92 84 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 11.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to Component Inspection . Is the inspection result normal?
YES>>
GO TO 13.
NO>>
GO TO 12.
- REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to EXHAUST MANIFOLD AND THREE WAY CATALYST : Exploded View .
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (NI-43897-18 or NI-43897-12)] and approved anti-seize lubricant (commercial service tool).
>>
INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to Inspection .
>>
INSPECTION END