Sensor Range Charts
COOLANT TEMP SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| 0 (-18) |
25,000 |
| 20 (-7) |
13,500 |
| 40 (4) |
7500 |
| 70 (21) |
3400 |
| 100 (38) |
1800 |
| 160 (71) |
450 |
| 212 (100) |
185 |
EGR TEMP SENSOR RESISTANCE (CALIF.)
| Temperature °F (°C) |
Ohms |
| 32 (0) |
27,000 |
| 104 (40) |
5800 |
| 212 (100) |
1000 |
MAP SENSOR VOLTAGE
| Altitude Feet |
Volts |
| Below 1000 |
3.8-5.5 |
| 1000-2000 |
3.6-5.3 |
| 2000-3000 |
3.5-5.1 |
| 3000-4000 |
3.3-5.0 |
| 4000-5000 |
3.2-4.8 |
| 5000-6000 |
3.0-4.6 |
| 6000-7000 |
2.9-4.5 |
| 7000-8000 |
2.8-4.3 |
| 8000-9000 |
2.6-4.2 |
MAT SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| 0 (-18) |
25,000 |
| 20 (-7) |
13,500 |
| 40 (4) |
7500 |
| 70 (21) |
3400 |
| 100 (38) |
1800 |
| 160 (71) |
450 |
| 212 (100) |
185 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
0.1 |
| Rich |
0.9 |
O2 SENSOR HEATING ELEMENT RESISTANCE TEST
| Application |
Ohms |
| Impulse & Stylus |
3.5-14 |
THROTTLE POSITION SENSOR VOLTAGE
| Position |
Volts |
| Closed Throttle |
0.48 |
| Open Throttle |
4.5 |
VEHICLE SPEED SENSOR CONTINUITY TEST
| Application |
Continuity |
| All Models |
4 Changes Per Revolution |
VEHICLE SPEED SENSOR VOLTAGE TEST
| Application |
Volts |
| All Models |
Less than 10 |