Installation Procedure

    Fig 1: Locating Battery Cable Harness Retainer & Conduit
    GM1313638Courtesy of GENERAL MOTORS CORP.
  1. Insert the battery positive cable (2) into the battery cables harness conduit (6).
  2. Close the battery cables harness retainer (5) at the engine wiring harness bracket (1).
  3. Fig 2: Locating Positive Battery Cable
    GM1313639Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  4. Connect the battery positive cable (2) to the starter and install the starter terminal nut (1).

    Tighten:  Tighten the battery positive cable to starter terminal nut to 9 N.m (80 lb in).

  5. Install the left wheelhouse liner. Refer to Wheelhouse Liner Replacement - Front in Body Front End.
  6. Lower the vehicle.
  7. Fig 3: Locating Positive Cable
    GM1313640Courtesy of GENERAL MOTORS CORP.
  8. Insert the battery positive cable (4) into the upper portion of the battery cables harness conduit (6).
  9. Install the nut (3) securing the battery positive cable (4) to the underhood fuse block (1).

    Tighten:  Tighten the battery positive cable to underhood fuse block nut to 9 N.m (80 lb in).

  10. Install the underhood fuse block cover to the underhood fuse block, engaging the locking tabs.
  11. Fig 4: View Of Battery Cable Harness Retainer
    GM1313637Courtesy of GENERAL MOTORS CORP.
  12. Close the battery cables harness retainers (3, 4).
  13. Fig 5: View Of Battery Cables
    GM1313634Courtesy of GENERAL MOTORS CORP.
  14. Clean any existing corrosion from the battery terminal and battery cable using a wire brush.
  15. Connect the battery positive cable to the battery.

    Tighten:  Tighten the battery cable nut (4) to 9 N.m (80 lb in).

  16. Close the protective cover (3) over the battery positive cable terminal.
  17. Connect the battery negative cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .