Servo Vacuum Test
- Remove cruise control cable from throttle body. Disconnect cruise control 4-pin servo connector. Disconnect vacuum hose at servo. Apply battery voltage to terminal No. 2 (Dark Blue/Red wire) at servo connector. Using jumper wire, ground remaining 3 terminals at servo connector.