Theory Of Operation
For an aged O2 Sensor, the response rate to the air/fuel change is slower than when it was new. The O2 Sensor tends to move less with the same air/fuel changes in a given time frame. Therefore by observing the activity of voltage readings from the upstream O2 Sensor, the quality of the O2 Sensor can be detected.