| 1 |
CHECK FUNCTIONALITY OF THE LOCK CYLINDER |
Continue to Step 2 |
If any signs of forced entry on the lock cylinder |
Replace the lock cylinder |
| Check for signs of tampering on the glove box lock cylinder. |
| 2 |
VERIFICATION OF LOCK CYLINDER OPENING |
Continue to Step 3 |
Foreign objects found |
Replace the lock cylinder |
| Check that the lock cylinder opening is free of foreign objects |
| 3 |
CHECK FUNCTIONALITY OF THE LOCK CYLINDER |
End of diagnosis |
The key continues to fail to be inserted into the lock cylinder |
Proceed to Step 4 |
| Through the opening of the lock cylinder, spray a small amount of lubricant (avoid contact with the aesthetic parts). |
| Try to re-insert the key. |
| 4 |
CHECK FUNCTIONALITY OF THE LOCK CYLINDER |
End of diagnosis |
The key continues to fail to be inserted into the lock cylinder even once removed from the board |
Replace the lock cylinder |
| Pull the lock cylinder from the door; verify the integrity and functionality of the lock cylinder itself. |
| Try to re-insert the key in the cylinder only. |