LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2002 >> Optima SE V6-2.7L >> Repair and Diagnosis >> Heating and Air Conditioning >> Ambient Temperature Sensor / Switch HVAC >> Testing and Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection




1. Disconnect battery terminal (-).
2. Detach the harness of the ambient temperature sensor.
3. Measure the resistance as shown.

Resistance 20 °C 36.5 ± 2.3 kOhms