Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
1.
Disconnect battery terminal (-).
2.
Detach the harness of the ambient temperature sensor.
3.
Measure the resistance as shown.
Resistance
20 °C 36.5 ± 2.3 kOhms