DTC C1604 Ecu Hardware Error: DTC Detecting Condition
DETECTING CONDITION AND POSSIBLE CAUSE
| Item |
Detecting Condition |
Possible cause |
| Case 1 |
DTC Strategy |
|
|
| Monitoring Period |
- Once per loop during EEPROM write access
|
| Enable Conditions |
|
| Fail Safe |
- The ABS/TCS/ESC functions are deactivated.
- The ABS/TCS/ESC warning lamps are activated.
|
| Case 2 |
DTC Strategy |
- Monitoring the Valve Solenoids
|
| Monitoring Period |
|
| Enable Conditions |
- A failure is detected if the valve relay is switched off and the reference voltage of solenoid valve > 1.5V continuously for 56ms.
- A failure is detected if the voltage drop at the activated low-side driver exceeds 2.0V or the voltage drop at one or more deactivated low-side drivers does not reach 2,0V continuously for 56ms.
|
| Fail Safe |
- The ABS/EBD/TCS/ESC functions are deactivated.
- The ABS/EBD/TCS/ESC warning lamps are activated.
|
| Case 3 |
DTC Strategy |
- Temperature Sensor Monitoring
|
| Monitoring Period |
|
| Enable Conditions |
- A temperature sensor failure is detected if the failure event has occurred 5 times.
|
| Fail Safe |
- The temperature value is set to -30 °C.
- The all warning lamps are not activated.
|
| Case 4 |
DTC Strategy |
- Long-Time Monitoring of the ESC Function
|
| Monitoring Period |
- once per loop during active ESC
|
| Enable Conditions |
- A failure is detected if the ESC function is active for more than 15s without a direction change of the calculated additional yaw torque.
|
| Fail Safe |
- The TCS/ESC functions are deactivated.
- The TCS/ESC warning lamps are activated.
|