Blower Motor Relay: Testing and Inspection

BLOWER RELAY

INSPECTION
Check for continuity between the terminals.
1. There should be continuity between No.1 and No.4 terminals when power and ground are connected No.2 and No.3 terminals.




2. There should be no continuity between No.1 and No.4 terminals when power is disconnected.
3. If the blower motor voltage is not operated well, substitute with a known-good blower relay and check for proper operation.
4. If the problem is corrected, replace the blower relay.