LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2008 >> Rio Base, Standard >> Repair and Diagnosis >> Engine Performance >> Ignition System >> General (Charging, Ignition & Starting) >> The Micro 570 Analyzer >> Charging System Test Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Charging System Test Procedure

  1. Press ENTER to begin charging system test.
    Fig 1: MICRO 570 Analyzer Screen Display - PRESS ENTER FOR CHARGING TEST
    G04861911Courtesy of KIA MOTORS AMERICA, INC.
  2. If ENTER button is pressed, the tester displays the actual voltage of alternator.

    Press ENTER to test the charging system.

    Fig 2: MICRO 570 Analyzer Screen Display - ALT VOLTS
    G04861912Courtesy of KIA MOTORS AMERICA, INC.
  3. Turn off all electrical load and rev engine for 5 seconds with pressing the accelerator pedal.
    Fig 3: MICRO 570 Analyzer Screen Display - LOADS OFF
    G04861913Courtesy of KIA MOTORS AMERICA, INC.
  4. Press ENTER.
    Fig 4: MICRO 570 Analyzer Screen Display - LOADS OFF
    G04861914Courtesy of KIA MOTORS AMERICA, INC.
  5. The MICRO 570 analyzer charging system output at idle for comparison to other readings.
    Fig 5: MICRO 570 Analyzer Screen Display - ***TESTING***
    G04861915Courtesy of KIA MOTORS AMERICA, INC.
  6. Take a relevant action according to the test results by referring to the table below after shutting off the engine and disconnect the tester clamps from the battery.
    Fig 6: MICRO 570 Analyzer Screen Display - DIODE RIPPLE NORMAL
    G04861916Courtesy of KIA MOTORS AMERICA, INC.
CHARGING SYSTEM TEST RESULTS

RESULT ON PRINTER REMEDY
Charging system normal/Diode ripple normal Charging system is normal
No charging voltage Alternator does not supply charging current to battery
=> Check belts, connection between generator and battery
Replace belts or cable or generator as necessary
Low charging voltage Alternator does not supply charging current to battery and electrical load to system fully
=> Check belts and generator and replace as necessary
High charging voltage The voltage from generator to battery is higher than normal limit during voltage regulating.
=> Check connection and ground and replace regulator as necessary
=> Check electrolyte level in the battery
Excess ripple detected One or more diodes in the generator is not functioning properly
=> Check generator mounting and belts and replace as necessary