Charging System Test Procedure
- Press ENTER to begin charging system test.
- If ENTER button is pressed, the tester displays the actual voltage of alternator.
Press ENTER to test the charging system.
- Turn off all electrical load and rev engine for 5 seconds with pressing the accelerator pedal.
- Press ENTER.
- The MICRO 570 analyzer charging system output at idle for comparison to other readings.
- Take a relevant action according to the test results by referring to the table below after shutting off the engine and disconnect the tester clamps from the battery.
CHARGING SYSTEM TEST RESULTS
| RESULT ON PRINTER | REMEDY |
|---|---|
| Charging system normal/Diode ripple normal | Charging system is normal |
| No charging voltage | Alternator does not supply charging current to battery => Check belts, connection between generator and battery Replace belts or cable or generator as necessary |
| Low charging voltage | Alternator does not supply charging current to battery and electrical load to system fully => Check belts and generator and replace as necessary |
| High charging voltage | The voltage from generator to battery is higher than normal limit during voltage regulating. => Check connection and ground and replace regulator as necessary => Check electrolyte level in the battery |
| Excess ripple detected | One or more diodes in the generator is not functioning properly => Check generator mounting and belts and replace as necessary |