LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2010 >> Rondo L4-2.4L >> Repair and Diagnosis >> Heating and Air Conditioning >> Housing Assembly HVAC >> Service and Repair >> Blower Unit >> Repair Procedures
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Repair Procedures





REPLACEMENT

1. Disconnect the negative (-) battery terminal.
2. Remove the crash pad. Dashboard / Instrument Panel
3. Disconnect the connectors from the intake actuator, the blower motor and power mosfet.
4. Remove the cowl cross bar assembly. Dashboard / Instrument Panel
5. Remove the blower unit (A) from the heater unit after loosening the mounting bolt and 3 screws.





NOTE:
- Make sure that there is no air leaking out of the blower and duct joints.

6. Installation is the reverse order of removal.