Monitor GDS Data

  1. Allow the engine to cool completely
  2. Run the cold engine at idle for 5 minutes and observe cooling fan status.
    NOTE: Ensure that the A/C is OFF
  3. Check the engine coolant temperature parameter at idle with the GDS.
  4. Is the engine coolant temperature increase to above 50°C (122°F)

    YES 

    NO 

    • Go to next step as below
  5. Are the cooling fans running when engine coolant temperature is low (less than approximately 98°C (208°F)) with A/C OFF?

    YES 

    NO 

    • With ignition "ON", Install GDS and select "COOLING FAN RELAY" on the Actuation Test mode. - Activates "COOLING FAN RELAY" by pressing "STRT (F1)" key - Repeat this procedure 4 or 5 times to ensure cooling fan reliability. - If cooling fan works properly, go to next step as below- If NG, check for intermittent fault caused by poor contact in the sensor's and/or PCM/ECM's connector. Repair as necessary and go to "Verification Of Vehicle Repair " procedure.