Component Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
IGPM component | 2 (P-CAN High) | IGPM component | 1 (P-CAN High) | Approx. 120 Ω |
| ECM component | 55 (P-CAN Low) | ECM component | 77 (P-CAN Low) | Approx. 120 Ω | |
Good
- If no problems were found with the circuits or connectors, check the Electric Water Pump and go to "Verification Of Repair " procedure.
No Good
- If no problems were found with the circuits or connectors, replace the IGPM or ECM and go to "Verification Of Repair " procedure.