Variable Valve Timing Solenoid: Service and Repair


Variable Camshaft Timing (VCT) Oil Control Solenoid

Service Repair No - 12.30.60


Removal

NOTE: Removal of the RH is similar to this procedure.

1. Disconnect the battery ground cable.
2. Remove the valve cover.

CAUTION: Before the disconnection or removal of any components, ensure the area around joint faces and connections are clean. Plug any open connections to prevent contamination.

3. Remove the variable camshaft timing (VCT) oil control solenoid.
^ Remove the bolt.





Installation
1. To install, reverse the removal procedure.
^ Clean the component mating faces.
^ Tighten the bolt to 10 Nm (7 ft. lbs.).