LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 1996 >> LX 450 >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel >> Component Testing >> Hazard Warning Switch Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Hazard Warning Switch Test

  1. Ensure HAZARD-HORN and/or TURN fuses are good. Ensure flasher is good. See TURN SIGNAL FLASHER LOCATION  table. With hazard warning switch removed from dash, ensure voltage is at switch wiring harness connector terminal No. 8. See Fig 1. If voltage does not exist, check/repair fuses and wiring circuit. If voltage exists, disconnect switch from connector.
  2. Using DVOM, ensure switch continuity exists between indicated terminals with switch in specified position. Refer to the HAZARD WARNING SWITCH CONTINUITY TEST  table. If continuity is not as specified, replace switch. If continuity is as specified, check wiring circuit. See WIRING DIAGRAMS .
TURN SIGNAL FLASHER LOCATION

Model Location
LX450 In Relay Block No. 1, Behind Left Kick Panel
Fig 1: Identifying Hazard Warning Switch Terminals
G93I02705Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
HAZARD WARNING SWITCH CONTINUITY TEST

Switch Position Terminal Numbers Continuity
LX450 (1)
Off 7 & 10 Yes
On 4, 5, 6 & 9; 7 & 8 Yes
(1) Terminals No. 2 and 3 are for switch illumination bulb.