Converter Sleeve Runout Check
Temporarily mount torque converter to drive plate. Mount a dial indicator with needle resting on converter sleeve. See Fig 1. Rotate converter. If runout exceeds .012" (.30 mm), reposition converter on drive plate and recheck runout.