Intake Air Control Valve Assembly (ES300)
With 7.9 in. Hg (26.7 kPa) of vacuum applied to actuator, ensure actuator rod moves. One minute after applying vacuum, check that actuator rod does not return. See Fig 1. If operation is not as specified, replace intake air control valve assembly.