Yaw Rate Sensor: Installation
- To install, reverse removal procedure. Tighten the 2 yaw rate sensor bolts to specification. See TORQUE SPECIFICATIONS .
- Perform yaw rate sensor zero point calibration. See YAW RATE SENSOR ZERO POINT CALIBRATION under PROGRAMMING.
- Check VSC sensor signal. See SYSTEM TESTING .