Section 326 (Interior Light System): Inspection
- INSPECT FRONT PERSONAL LIGHT SWITCH CONTINUITY SPECIFIED CONDITION
Switch position Tester connection Specified condition OFF - No continuity ON 1-2 Continuity If continuity is not as specified, replace the light assembly or the bulb.
- INSPECT FRONT PERSONAL LIGHT SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFIED CONDITIONTester connection Condition Specified condition 2-Ground Always Continuity 1 - Ground Always Battery positive voltage If circuit is not as specified, inspect power source or wire harness.
- INSPECT REAR PERSONAL LIGHT SWITCH CONTINUITY SPECIFICATION CONDITION
Switch position Tester connection Specified condition OFF - No continuity ON 1 - 4 Continuity If continuity is not as specified, replace the light assembly or the bulb.
- INSPECT REAR PERSONAL LIGHT SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side.
SPECIFICATION CONDITIONTester connection Condition Specified condition 1 -Ground Always Continuity 4 - Ground Always Battery positive voltage If circuit is not as specified, inspect power source or wire harness.
- INSPECT ROOM LIGHT SWITCH CONTINUITY SPECIFICATION CONDITION
Switch position Tester connection Specified condition Room Light Switch OFF - No continuity Room Light Switch DOOR 3-4 Continuity Room Light Switch ON 1 - 4 Continuity If continuity is not as specified, replace the light assembly or the bulb.
- INSPECT ROOM LIGHT SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side.
SPECIFICATION CONDITIONTester connection Condition Specified condition 1-Ground Always Continuity 4-Ground Always Battery positive voltage If circuit is not as specified, inspect power source or the wire harness.
- INSPECT REAR ROOM LIGHT SWITCH CONTINUITY
- Disconnect the connector from the room light assembly.
- Turn the room light switch ON, and check that continuity exists between terminal 2 and body ground.
- Turn the room light switch DOOR, and check that continuity exists between terminal 1 and 2.
If operation is not as specified, replace the light assembly or the bulb.
- INSPECT REAR ROOM LIGHT SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONTester connection Condition Specified condition 1 - Ground Always Battery positive voltage If circuit is not as specified, inspect power source or the wire harness.
- INSPECT VANITY LIGHT CONTINUITY SWITCH POSITION
Switch position Tester connection Specified condition OFF (closed) - No continuity ON (opened) 1 - 2 Continuity If continuity is not as specified, replace the vanity light assembly or the bulb.
- INSPECT VANITY LIGHT CIRCUIT
Disconnect the connector from the light and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONTester connection Condition Specified condition 1 - Ground Always Continuity 2-Ground Always Battery positive voltage If circuit is not as specified, inspect power source or the wire harness.
- INSPECT DOOR COURTESY SWITCH CONTINUITY
- Check that continuity exists between terminal and the switch body with the switch ON (switch pin released).
- Check that no continuity exists between terminals and the switch body with the switch OFF (switch pin pushed).
If continuity is not as specified, replace the switch.
- INSPECT DOOR COURTESY SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONTester connection Condition Specified condition 1 - Ground Always Battery positive voltage If circuit is not as specified, inspect power source or the wire harness.
- INSPECT DOOR COURTESY LIGHT CONTINUITY
Using an ohmmeter, check that continuity exists between terminals.
If continuity is not as specified, replace the light assembly or the bulb.
- INSPECT DOOR COURTESY LIGHT CIRCUIT (See PROBLEM SYMPTOMS TABLE )
- INSPECT BACK DOOR COURTESY SWITCH CONTINUITY SPECIFICATION CONDITION
Switch position Tester connection Specified condition OFF (closed) - No continuity ON (opened) 1 - 2 Continuity If continuity is not as specified, replace the back door lock assembly.
- INSPECT BACK DOOR COURTESY SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONTester connection Condition Specified condition 2 - Ground Always Continuity If circuit is not as specified, inspect power source or the wire harness.
- INSPECT GLOVE COMPARTMENT DOOR COURTESY SWITCH CONTINUITY SPECIFICATION CONDITION
Switch position Tester connection Specified condition OFF (closed) - No continuity ON (opened) 1 - 2 Continuity If continuity is not as specified, replace the switch.
- INSPECT LICENCE PLATE LIGHT CONTINUITY
Using an ohmmeter, check that continuity exists between terminals.
If continuity is not as specified, replace the light assembly or the bulb.
- INSPECT FOOT LIGHT CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONCondition Tester connection Specified condition Ignition switch ON and door open 1 - Ground Battery positive voltage Always 2 - Ground Continuity If circuit is not as specified, inspect power source or the wire harness.
- INSPECT INSIDE DOOR HANDLE ILLUMINATION CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONCondition Tester connection Specified condition Ignition switch ON and door open 1 - Ground Battery positive voltage Always 2 - Ground Continuity If circuit is not as specified, inspect power source or the wire harness.
- INSPECT SIDE STEP LIGHT CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONCondition Tester connection Specified condition Ignition switch ON and door open 1 - Ground Battery positive voltage Always 2 - Ground Continuity If circuit is not as specified, inspect power source or the wire harness.
- INSPECT OUTER FOOT LIGHT CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONCondition Tester connection Specified condition Ignition switch ON and door open 1 - Ground Battery positive voltage Always 2 - Ground Continuity If circuit is not as specified, inspect power source or the wire harness.
- INSPECT CENTER CONSOLE SPOT LIGHT CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
SPECIFICATION CONDITIONCondition Tester connection Specified condition Ignition switch ON and door open 1 - Ground Battery positive voltage Always 2 - Ground Continuity If circuit is not as specified, inspect power source or the wire harness.