Transmission Wire: Notes
CAUTION:
When working with FIPG material, perform the following:
- Using a razor blade and gasket scraper, remove all the old, FIPG material from the gasket surfaces.
- Thoroughly clean all components to remove any loose material.
- Clean both sealing surfaces with a non-residue solvent.
- Apply FIPG in continuous line width approximately 0.04 in. (1 mm) wide along the sealing surface.
- Parts must be assembled within 10 minutes of application. Otherwise, the FIPG material must be removed and reapplied.