SFI System (3MZ-FE): Inspection
- INSPECT MASS AIR FLOW METER
- Output voltage inspection.
- Apply battery voltage across terminals 1 (+B) and 2 (E2G).
- Connect the positive (+) tester probe to terminal VG, and negative (-) tester probe to terminal E2G.
- Blow air into the MAF meter, and check that the voltage output fluctuates.
- Resistance inspection.
- Using an ohmmeter, measure the resistance between terminals 4 (THA) and 5 (E2).
Resistance:
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Using an ohmmeter, measure the resistance between terminals 4 (THA) and 5 (E2).
- Output voltage inspection.
- INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSY
- Resistance inspection.
- Using an ohmmeter, measure the resistance between the terminals.
Resistance: 6.9 to 7.9 Ω at 20°C (68°F)
- Using an ohmmeter, measure the resistance between the terminals.
- Movement inspection.
- Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.NOTE: Confirm the valve moves freely and does not stick in any position.
HINT:
Bad returning of the valve by catching foreign objects causes subtle pressure leak. The subtle pressure leak will cause the cam to advance, and this condition will set a DTC.
- Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
- Resistance inspection.
- INSPECT ACCELERATOR PEDAL ROD ASSY
- Resistance inspection
- Using an ohmmeter, measure the resistance between the terminals.
Resistance:
ACCELERATOR PEDAL ROD ASSY CONNECTOR TERMINALS RESISTANCE SPECIFICATIONSSymbols (Terminal No.) Resistance VPA2 (3) - EP1 (5) 5.0 kΩ or less VPA1 (6) - EP2 (2) 5.0 kΩ or less VCP1 (4) - EP1 (5) 2.25 to 4.75 kΩ VCP2 (1) - EP2 (2) 2.25 to 4.75 kΩ
- Using an ohmmeter, measure the resistance between the terminals.
- Resistance inspection
- INSPECT THROTTLE BODY ASSY
- INSPECT E.F.I. ENGINE COOLANT TEMPERATURE SENSOR
- Resistance inspection.
- Using an ohmmeter, measure the resistance between each terminal.
Resistance:
2.32 to 2.59 kΩ at Approx. 20°C (68°F)
0.310 to 0.326 kΩ at Approx. 80°C (176°F)
NOTE: In case of checking the water temperature sensor in the water, be careful not to allow water to go into the terminals, and after checking, dry the sensor.
- Using an ohmmeter, measure the resistance between each terminal.
- Resistance inspection.
- INSPECT KNOCK SENSOR
- Continuity inspection.
- Using an ohmmeter, measure the resistance between the terminals.
Resistance: 120 to 280 kΩ at 20°C (68°F)
HINT:
If the resistance is not specified, replace the sensor.
- Using an ohmmeter, measure the resistance between the terminals.
- Continuity inspection.
- INSPECT EFI RELAY
- INSPECT CIRCUIT OPENING RELAY