LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2006 >> IS 250 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 3 (Engine Control System (2GR-FSE)) >> SFI System >> DTC P0420 Catalyst System Efficiency Below Threshold (Bank 1); DTC P0430 Catalyst System Efficiency Below Threshold (Bank 2) >> Monitor Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Monitor Description

WARNING: This page is about a different car, the 2006 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.

The ECM uses sensors mounted in front of and behind the Three-Way Catalytic Converter (TWC) to monitor its efficiency.

The first sensor, the Air-Fuel Ratio (A/F) sensor, sends pre-catalyst information to the ECM. The second sensor, the Heated Oxygen (HO2) sensor, sends post-catalyst information to the ECM.

In order to detect any deterioration in the TWC, the ECM calculates the Oxygen Storage Capacity (OSC) of the TWC. This calculation is based on the voltage output of the HO2 sensor while performing active airfuel ratio control, rather than the conventional detecting method, which uses the locus ratio.

The OSC value is an indication of the oxygen storage capacity of the TWC. When the vehicle is being driven with a warm engine, active air-fuel ratio control is performed for approximately 15 to 20 seconds. When it is performed, the ECM deliberately sets the air-fuel ratio to lean or rich levels. If a rich-lean cycle of the HO2 sensor is long, the OSC becomes greater. There is a direct correlation between the OSCs of the HO2 sensor and the TWC.

The ECM uses the OSC value to determine the state of the TWC. If any deterioration has occurred, it illuminates the MIL and sets a DTC.

DTC DETECTION CONDITION AND TROUBLE AREA

DTC No. DTC Detection Condition Trouble Area
P0420 OSC value smaller than standard value under active air-fuel ratio control (2 trip detection logic)
  • Gas leakage from exhaust system
  • A/F sensor (bank 1 sensor 1)
  • HO2 sensor (bank 1 sensor 2)
  • Exhaust manifold (TWC)
P0430 OSC value smaller than standard value under active air-fuel ratio control (2 trip detection logic)
  • Gas leakage from exhaust system
  • A/F sensor (bank 2 sensor 1)
  • HO2 sensor (bank 2 sensor 2)
  • Exhaust manifold (TWC)

HINT: