Inspection Procedure
- INITIALIZE POWER WINDOW CONTROL SYSTEM
- Initialize the power window regulator motor assembly (on the driver side) (See INITIALIZATION ).
- Check that the power window operates normally by opening and closing the window.
OK: Driver side power window operates normally.
NG: REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side)
OK: Go to Next Step
- CHECK WHETHER PARTS HAVE BEEN INSTALLED CORRECTLY
- Check that the power window components (on the driver side) are installed correctly.
OK: Power window components (on driver side) are installed correctly.
HINT:
When the power window components are installed correctly, the problem has been caused by battery disconnection while the engine switch is on (IG), improper installation of the power window components or the motor being overheated.
NG: INSTALL PARTS CORRECTLY
OK: END
- Check that the power window components (on the driver side) are installed correctly.