On-Vehicle Inspection
- INSPECT VSC NO. 1 (FAIL SAFE) RELAY
- Remove the VSC No. 1 (fail safe) relay.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3 - 5 Always 10 kΩ or higher 3 - 5 Apply B+ between terminals 1 and 2 Below 1 Ω If the value is not as specified, replace the VSC No. 1 (fail safe) relay.
- INSPECT VSC NO. 2 RELAY
- Remove the VSC No. 2 relay.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 3 - 5 Always 10 kΩ or higher 3 - 5 Apply B+ between terminals 1 and 2 Below 1 Ω If the value is not as specified, replace the VSC No. 2 relay.