On-Vehicle Inspection
- INSPECT NO. 2 IGNITION RELAY
- Using an ohmmeter, measure the resistance between each terminal.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Specified Condition 3 - 5 10 kΩ or higher Below 1 Ω (Apply battery voltage between terminals 1 and 2) Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the No. 2 ignition relay.
- Using an ohmmeter, measure the resistance between each terminal.