WATER TEMPERATURE GAUGE: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Water temperature data is interrupted for 5 seconds Gauge needle indicates below "C" Water temperature data is received

FUEL SIGNAL (FUEL INJECTION SIGNAL): 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
While engine switch is in on (IG) position, fuel injection signal is interrupted for 60 seconds Fuel gauge calibration is performed using average fuel consumption data Engine switch is turned from off to on (IG) and normal data is received

FUEL SIGNAL (GAUGE SIGNAL): 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
While engine switch is in the on (IG) position, sender signal is interrupted for 60 seconds and malfunction signal is received from one of the gauges for 10 to 20 seconds Needle indicates "E", and warning light comes on Engine switch is turned from off to on (IG) and normal data is received

SHIFT INDICATOR: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
"P to D" data is interrupted for 3 seconds All indicators go off Normal data is received
"S" data is interrupted for 3 seconds "S" indicator goes off Normal data is received

GEAR POSITION INDICATOR (1 TO 6): 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Gear position data is interrupted for 3 seconds or malfunction signal is received Indicator goes off Normal data is received

ABS AND BRAKE: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
ABS and brake data is interrupted for 10 seconds Warning light comes on Normal data is received

DOOR: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted Data received most recently remains displayed Normal data is received

TAIL: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted Data received most recently remains displayed Normal data is received

BEAM: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received

TAIL OR HEAD: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received

FR FOG: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Regular data is interrupted for 10 seconds or more Indicator goes off Normal data is received.

AIRBAG: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Airbag data is interrupted for 10 seconds or there is malfunction in the meter's internal CPU Warning light comes on Normal data is received

OUTSIDE TEMP: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Abnormal data and sensor malfunctioning data are received "-°F" is displayed Normal data is received
Outside temperature, data is interrupted for 10 seconds "E" is displayed Normal data is received

MULTI-INFORMATION: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Cruise information data is interrupted for 60 seconds Display becomes blank (only measurement units are displayed) Normal data is received

LIGHT CONTROL RHEOSTAT: 

FAIL-SAFE CHART

Condition Fail-safe Operation Fail-safe Deactivation Condition
Rheostat data is interrupted for 10 seconds or abnormal data is received Display remains in daytime mode Normal data is received