Fail-Safe Chart
WATER TEMPERATURE GAUGE:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Water temperature data is interrupted for 5 seconds | Gauge needle indicates below "C" | Water temperature data is received |
FUEL SIGNAL (FUEL INJECTION SIGNAL):
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While engine switch is in on (IG) position, fuel injection signal is interrupted for 60 seconds | Fuel gauge calibration is performed using average fuel consumption data | Engine switch is turned from off to on (IG) and normal data is received |
FUEL SIGNAL (GAUGE SIGNAL):
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| While engine switch is in the on (IG) position, sender signal is interrupted for 60 seconds and malfunction signal is received from one of the gauges for 10 to 20 seconds | Needle indicates "E", and warning light comes on | Engine switch is turned from off to on (IG) and normal data is received |
SHIFT INDICATOR:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| "P to D" data is interrupted for 3 seconds | All indicators go off | Normal data is received |
| "S" data is interrupted for 3 seconds | "S" indicator goes off | Normal data is received |
GEAR POSITION INDICATOR (1 TO 6):
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Gear position data is interrupted for 3 seconds or malfunction signal is received | Indicator goes off | Normal data is received |
ABS AND BRAKE:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| ABS and brake data is interrupted for 10 seconds | Warning light comes on | Normal data is received |
DOOR:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Regular data is interrupted | Data received most recently remains displayed | Normal data is received |
TAIL:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Regular data is interrupted | Data received most recently remains displayed | Normal data is received |
BEAM:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
TAIL OR HEAD:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
FR FOG:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received. |
AIRBAG:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Airbag data is interrupted for 10 seconds or there is malfunction in the meter's internal CPU | Warning light comes on | Normal data is received |
OUTSIDE TEMP:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Abnormal data and sensor malfunctioning data are received | "-°F" is displayed | Normal data is received |
| Outside temperature, data is interrupted for 10 seconds | "E" is displayed | Normal data is received |
MULTI-INFORMATION:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Cruise information data is interrupted for 60 seconds | Display becomes blank (only measurement units are displayed) | Normal data is received |
LIGHT CONTROL RHEOSTAT:
FAIL-SAFE CHART
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
|---|---|---|
| Rheostat data is interrupted for 10 seconds or abnormal data is received | Display remains in daytime mode | Normal data is received |