Yaw Rate And Acceleration Sensor: Installation
- INSTALL YAW RATE SENSOR
- Install the sensor with the 2 bolts.
Torque: 15 N*m (153 kgf*cm, 11 ft.*lbf)
NOTE:- Do not damage the sensor.
- Make sure that the sensor is installed securely.
- Install the 2 wire harness clamps.
- Connect the sensor connector.
- Install the sensor with the 2 bolts.
- INSTALL NO. 1 CONSOLE BOX DUCT
- Install the No. 1 duct with the clip.
- INSTALL NO. 2 CONSOLE BOX DUCT
- Install the No. 2 duct with the 2 clips.
- INSTALL CONSOLE BOX (See INSTALLATION )
- INSTALL CONSOLE BOX REGISTER ASSEMBLY (See INSTALLATION )
- INSTALL CONSOLE BOX PLATE (See INSTALLATION )
- INSTALL INSTRUMENT PANEL FINISH PANEL END LH (See INSTALLATION )
- INSTALL INSTRUMENT PANEL FINISH PANEL END RH (See INSTALLATION )
- INSTALL CONSOLE UPPER PANEL ASSEMBLY (See INSTALLATION )
- INSTALL FRONT CONSOLE UPPER PANEL GARNISH (See INSTALLATION )
- PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION
- Perform the yaw rate sensor zero point calibration (see CALIBRATION ).
- CHECK YAW RATE SENSOR SIGNAL
- Check the yaw rate sensor signal (see TEST MODE PROCEDURE ).