Combination Meter: Installation
- INSTALL COMBINATION METER GLASS
- Attach the 7 claws to install the glass.
- Install the combination meter glass's wire harness with the clamps.
- Connect the 3 connectors.
- Close the cover and attach the 2 claws.
- INSTALL COMBINATION METER ASSEMBLY
- Connect the connector.
- Install the combination meter with the 4 screws.
- INSTALL INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
- Connect the connector.
- Attach the 5 clips to install the cluster finish panel.
- INSTALL STEERING COLUMN COVER UPPER (See INSTALLATION )
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- PERFORM INITIALIZATION
- Perform initialization (see
INITIALIZATION (2006/02-2006/07)
).NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
- Perform initialization (see
INITIALIZATION (2006/02-2006/07)
).
- CHECK SRS WARNING LIGHT
- Check the SRS warning light (see DIAGNOSIS SYSTEM (2006/02-2006/07) ).