Power Window Regulator Motor: Inspection
- INSPECT POWER WINDOW REGULATOR MOTOR (FRONT RH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Apply battery voltage to the motor connector according to the table below.NOTE: Do not apply battery voltage to any terminals except terminals 1 and 2.
Standard
MEASUREMENT CONDITION AND SPECIFIED CONDITION TABLEMeasurement Condition Specified Condition Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2Motor gear rotates clockwise Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1Motor gear rotates counterclockwise - Apply battery voltage to the motor connector according to the table below.
- INSPECT POWER WINDOW REGULATOR MOTOR (FRONT LH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Apply battery voltage to the motor connector according to the table below.NOTE: Do not apply battery voltage to any terminals except terminals 1 and 2.
Standard
MEASUREMENT CONDITION AND SPECIFIED CONDITION TABLEMeasurement Condition Specified Condition Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1Motor gear rotates clockwise Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2Motor gear rotates counterclockwise - Apply battery voltage to the motor connector according to the table below.
- INSPECT POWER WINDOW REGULATOR MOTOR (REAR RH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Apply battery voltage to the motor connector according to the table below.NOTE: Do not apply battery voltage to any terminals except terminals 1 and 2.
Standard
MEASUREMENT CONDITION AND SPECIFIED CONDITION TABLEMeasurement Condition Specified Condition Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1Motor gear rotates clockwise Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2Motor gear rotates counterclockwise - Apply battery voltage to the motor connector according to the table below.
- INSPECT POWER WINDOW REGULATOR MOTOR (REAR LH)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Apply battery voltage to the motor connector according to the table below.NOTE: Do not apply battery voltage to any terminals except terminals 1 and 2.
Standard
MEASUREMENT CONDITION AND SPECIFIED CONDITION TABLEMeasurement Condition Specified Condition Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2Motor gear rotates clockwise Battery positive (+) → Terminal 2
Battery negative (-) → TerminalMotor gear rotates counterclockwise - Apply battery voltage to the motor connector according to the table below.