Light Control Rheostat: Inspection
- INSPECT LIGHT CONTROL RHEOSTAT
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION REFERENCE TABLETester Connection Condition Specified condition 1 (T) - Body ground Ignition switch ON, Taillight switch OFF → ON Below 1 V → 10 to 14 V 2 (IG) - Body ground Ignition switch OFF → ON Below 1 V → 10 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION REFERENCE TABLETester Connection Condition Specified condition 5 (E) - Body ground Always Below 1 Ω - Check the resistance between terminal 4 (RV) and terminal 3 (T) when operating the light control rheostat volume knob. Also, check that the resistance changes continuously.
Standard resistance:
Turn the knob to maximum:
Approx. 10 kΩ
Turn the knob to minimum:
Approx. 0 kΩ
- Measure the voltage according to the value(s) in the table below.