Service Data
2UZ-FE EMISSION CONTROL - SERVICE DATA
| VSV for charcoal canister | Resistance | at 20°C (68°F) | 25 to 30 Ω |
| at 100°C (212°F) | 32 to 42 Ω | ||
| Vacuum switching valve assembly | Resistance | at 20°C (68°F) | 26 to 30 Ω |
| Heated oxygen sensor (Sensor 2) | Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity | |
| Air fuel ratio sensor (Sensor 1) | Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| Resistance | 1 (HT) - 4 (E1) | No continuity | |
| Pressure sensor | Voltage | AIP-E2 | 1.0 to 2.2 V |
| Vacuum switching valve assembly | Resistance | 1 - 2 | 33 to 39 Ω at 20°C (68°F) |
| 1-Body ground | 10 MΩ or higher | ||
| 21-Body ground | 10 MΩ or higher |